Sign In | Join Free | My burrillandco.com
Home > FLUKE >

Fluke 1770 Series Three-Phase Power Quality Analyzers F1770 Fluke 1732 and 1734 F1770 F1732 Electrical Energy Loggers FLUKE 1742 1746 1748 F1742 F1746

WUHU WANYI INDUSTRY CO.,LTD
Contact Now
    Buy cheap Fluke 1770 Series Three-Phase Power Quality Analyzers F1770 Fluke 1732 and 1734 F1770 F1732 Electrical Energy Loggers FLUKE 1742 1746 1748 F1742 F1746 from wholesalers
     
    Buy cheap Fluke 1770 Series Three-Phase Power Quality Analyzers F1770 Fluke 1732 and 1734 F1770 F1732 Electrical Energy Loggers FLUKE 1742 1746 1748 F1742 F1746 from wholesalers
    • Buy cheap Fluke 1770 Series Three-Phase Power Quality Analyzers F1770 Fluke 1732 and 1734 F1770 F1732 Electrical Energy Loggers FLUKE 1742 1746 1748 F1742 F1746 from wholesalers

    Fluke 1770 Series Three-Phase Power Quality Analyzers F1770 Fluke 1732 and 1734 F1770 F1732 Electrical Energy Loggers FLUKE 1742 1746 1748 F1742 F1746

    Ask Lasest Price
    Brand Name : Fluke
    Model Number : F1770 FLUKE 1742 1746 1748 F1742 F1746 F1748 FLUKE F1736 F1738 F1760
    Certification : CCCI
    Payment Terms : Western Union, T/T
    Supply Ability : 10-100
    Delivery Time : 7-10days
    • Product Details
    • Company Profile

    Fluke 1770 Series Three-Phase Power Quality Analyzers F1770 Fluke 1732 and 1734 F1770 F1732 Electrical Energy Loggers FLUKE 1742 1746 1748 F1742 F1746

    Specifications: Fluke 1770 Series Three-Phase Power Quality Analyzers

    Key features

    Voltage inputs
    Number of inputs4 inputs, 3 phases and neutral referenced to PE (5 connectors)
    Measurement category1000 V CAT III / 600 V CAT IV
    Maximum input voltage1000 V rms / 1000 V dc (1700 Vpk)
    Nominal voltage rangeWye and single phase: variable (50 V – 1000 V)
    Delta: Variable (100 V – 1000 V)
    IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 V
    Input impedance10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE
    BandwidthDC to 30 kHz for PQ measurements, excluding transients
    Resolution24-bit synchronous sampling
    Sampling frequency80 kS/s at 50/60 Hz
    Scaling1:1, variable for use of potential transformers
    Voltage transients
    Measurement range±8 kV
    Sampling rate1775: 1 MS/s
    1777: 1 MS/s, 20 MS/s
    BandwidthDC to 1 MHz
    TriggerAdjustable trigger level. Triggers on high-frequency components > 1.5 kHz
    Resolution14-bit synchronous sampling
    Current inputs
    Number of inputs4 inputs 3 phases and Neutral, range selected automatically to attached sensor
    RangeAC1 A to 1500 A with i17XX-FLEX1500 12
    1 A to 1500 A with i17XX-FLEX1500 18
    3 A to 3000 A with i17XX-FLEX3000 24
    6 A to 6000 A with i17XX-FLEX6000 36
    40 mA to 40 A with clamp i40s-EL
    4 A to 400 A with clamp i400s-EL
    DC20 A to 2000 A with 80i-2010-EL clamp
    BandwidthDC to 30 kHz
    Resolution24-bit synchronous sampling
    Sampling frequency80 kS/s at 50/60 Hz
    Scaling1:1, variable
    Input voltageClamp: 50 mV / 500 mV rms; CF 2.8
    Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4
    all at nominal probe range
    Input impedance11 kΩ
    Aux inputs
    Wired connection with 17XX-AUX adapter
    Number of inputs2
    Input rangeDirect: 0 V dc to ± 10 V dc
    0 V to 1000 V dc
    Input impedanceDirect: 2.92 MΩ
    Scale factorFormat: mx + b (gain and offset) user configurable
    Displayed unitsUser configurable (up to 8 characters, for example °C, psi, or m/s)
    Data acquisition voltage and current
    Input mains frequencyDC, 50/60 Hz  15 % (42.5 Hz … 57.5 Hz, 51 Hz … 69 Hz)
    Topologies1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta
    Data storageFluke 1773/1775: 8 GB internal (expandable with microSD card)
    Fluke 1777: 32 GB microSD card (installed)
    Memory sizeTypical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.
    The number of possible logging sessions and logging period depends on user requirements
    Real time accuracyInternal: 3 ppm (0.26 s per day, 8 s per month)
    NTP (internet time): Depending on internet latency, typical < 0.1 s absolute to UTC
    GPS: < 1 ms absolute to UTC
    Trend interval
    Measured parameterSee operator manual
    Trend intervalUser selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
    Averaging interval min/max valuesVoltage, Current: ½ cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)
    Aux, Power: 200 ms
    Total harmonic distortionTHD for voltage and current is calculated on 50 harmonics
    Power quality measurements
    Measured parameterSee operator manual
    Harmonicsh0 … h50
    % fund and RMS for voltage, current and power
    Phase angles for voltage and current up to h11
    Interharmonicsih0… ih50
    % fund and RMS for voltage and current
    Supraharmonics2–9 kHz with 200 Hz bins
    9–30 khz with 2 kHz bins
    RMS for voltage and current
    Harmonics measurement methodGrouped, sub-grouped and single harmonic bins according to IEC 61000-4-7.
    Method selected automatically based on configured PQ standard or user configurable.
    Total harmonic distortionCalculated on up to 50 harmonics (depends on selected PQ standard)
    Mains signaling2 frequencies in the range from 110 Hz to 3000 Hz
    EventsVoltageDip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients
    CurrentInrush current
    Triggered recordingsHalf cycle RMS of voltage and current for 10 s
    Waveform of voltage and current for 10/12 cycles
    Mains signaling: 200 ms RMS of mains signaling voltage up to 120 s
    Transients: Waveform of voltage
    (Fluke 1777: 1 MS/s or 20 MS/s, 500,000 pts, Fluke 1775: 1 MS/s, 25,000 pts)
    Standard compliance
    PowerIEEE 1459
    HarmonicsIEC 61000-4-7: Class 1
    IEEE 519 (short time and very short time harmonics)
    FlickerIEC 61000-4-15 Class F1
    Power qualityIEC 61000-4-30 Class A, IEC 62586 PQI-A-PI
    Power quality complianceEN 50160 + GOST + NEQUAL + NETCODE + FOL
    Interfaces
    Ethernet1 Gbit/s 1000BASE-T
    USB type AUSB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA
    USB-CUSB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)
    Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)
    USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA
    WiFi/BLE module1802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client mode
    Bluetooth 5.0/BLE
    Antenna: Internal and external2
    LTE/4G module3LTE-A Cat 12
    Worldwide LTE-A and UMTS/HSPA+ coverage
    Antenna: External2
    GPSMCX connector to attach a GNSS antenna for GPS/GLONASS2
    1 Not in 177X/BASIC versions
    2 Requires 5m extension cable, Fluke p/n 5263915
    3 Availability and supported providers vary by country. Check with your local Fluke representative.

    Electrical measurement accuracy

    ParameterRangeResolutionIntrinsic Accuracy at Reference Conditions
    % of Reading + % of Full Scale
    Voltage1000 V0.1 V0.1 % of nominal voltage
    in accordance with
    IEC 61000-4-30 Class A1,2
      ±(0.04 % + 0.004 %)3
    Voltage dips and swells-0.1 V0.2 % of Vnom1,2
    Voltage transients±8 kVpk-±5 % +0.25 %)
    Voltage harmonics/interharmonics100 %0.1 % / 0.1 mV≥1 % Vnom1:  ±2.5 % of rdg.
    <1 % Vnom1:  ±0.025 Vnom
    THD on voltage100 %0.1 % / 0.1 V±(2.5 % + 0.5 %)
    Voltage distortions 2-9 kHzMax 100 V0.1 mV±(2.5 % + 0.1 V)
    Voltage distortions 9-30 kHzMax 100 V0.1 mV±(2.5 % + 0.1 V)
    Current
    (Rogowski clamp mode)
    With iFlex 1500 A,
    i17XX-FLEX1500 18
    150 A
    1500 A
    0.01 %
    0.1 A
    ±(1 % + 0.02 %)
    With iFlex 3000 A,
    i17XX-FLEX3000 24
    300 A
    3000 A
    0.01 A
    0.1 A
    ±(1 % + 0.03 %)
    With iFlex 6000 A,
    i17XX-FLEX6000 36
    600 A
    6000 A
    0.1 A
    1 A
    ±(1.5 % + 0.03 %)
    With AC clamp 40 A,
    i40s-EL
    4 A
    40 A
    0.001 A
    0.01 A
    ±(0.7 % + 0.02 %)
    With AC clamp 400 A,
    i400s-EL
    40 A
    400 A
    0.01 A
    0.1 A
    ±(2 % + 0.2 %)
     ±(0.7 % + 0.1 %)
    With AC/DC clamp
    2000 A, 80i-2010s-EL
    200 A
    2000 A
    0.01 A
    0.1 A
    ±(0.8 % + 0.2 %)
    Current min/max100 %defined by accessoryx2 of intrinsic accuracy
    Current harmonics/interharmonics100 %0.1 % / 0.01 A≥3 % Inom:  ±2.5 % of rdg.4
    <3 % Inom:  ±0.15 % of Inom
    THD on current100 %0.1 %±(2.5 % + 0.5 %)
    Frequency42.5 Hz … 69 Hz0.001 Hz±0.01 Hz
    Voltage unbalance100 %0.1 %±0.15 %
    Current unbalance100 %0.1 %±0.15 %
    Flicker Pinst, Pst, Plt0 to 200.015 %
    Mains signaling voltageUp to 3 kHz
    0-15 % of Vnom
    0.1 V / 0.1 %1-3 % Vnom: ±0.15 % of Vnom
    3-15 % Vnom: ±5 % of rdg.
    AUX input±10 V0.1 mV±(0.2 % + 0.05 %)
    1 Nominal voltage in the range of 100 V to 690 V. Also known as Udin.
    2 0 °C to 45 °C: Intrinsic Accuracy x2. Outside of 0 °C to 45 °C: Intrinsic Accuracy x3
    3 Only for calibration laboratories
    4 With iFlex 1500A, I17XX-FLEX1500 18

    Power/Energy

    ParameterDirect Input1Clamp i40S-EL
    Power range W, VA, varClamp: 50 mV / 500 mV
    Rogowski: 15 mV / 150 mV
    4 A / 40 A
    Clamp: 50 W / 500 W
    Rogowski: 15 W / 150 W
    4k W / 40 kW
    Max. resolution W, VA, var0.1 W1 W / 10 W
    Phase (voltage to current)1±0.2°±1°
    ParameteriFlex 1500A, I17XX-FLEX1500 18iFlex 3000A, I17XX-FLEX3000iFlex 6000A, I17XX-FLEX6000
    Power range W, VA, var150 A / 1500 A300 A / 3000 A600 A / 6000 A
    150 kW / 1.5 MW300 kW / 3 MW600 kW / 6 MW
    Max. resolution W, VA, var0.1 kW / 1kW1 kW /10 kW1 kW / 10k W
    ParameterI17XX-FLEX1500 18I17XX-FLEX3000I17XX-FLEX6000
    Active power PPF ≥ 0.99150 A / 1500 A300 A / 3000 A600/6000 A
    1.2 % + 0.005 %1.2 % + 0.0075 %1.7 % + 0.0075 %
    Active energy Ea0.1 ≤ PF < 0.99(1.2+√(1-PF2)/(2 PF)) % + 0.005 %(1.2+√(1-PF2)/(2 PF)) % + 0.0075 %(1.7+√(1-PF2)/(2 PF)) % + 0.0075 %
    Apparent power S
    Apparent energy Eap
    0 ≤ PF ≤ 11.2 % + 0.005 %1.2 % + 0.0075 %1.7 % + 0.0075 %
    Reactive power Q
    Reactive energy Er
    0 ≤ PF ≤ 12.5 % of measured apparent power/energy
    Additional uncertainty
    (% of power high range)
    VP-N > 250 V0.02 %0.02 %0.02 %
    Phase (voltage to current)-0.28°0.28°0.28°

    1 Nominal voltage in the range of 100 V to 690 V. Also known as Udin.

    Reference Conditions

    Environmental: 23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %

    Input conditions: Cos Φ/PF=1, Sinusoidal signal f=50/60 Hz, power supply 120 V/230 V ±10 %.

    Current and power specifications: Input voltage >100V

    Input current > 10 % of current range

    Primary conductor of clamps or Rogowski coil in center position

    Temperature coefficient: Add 0.1 x specified accuracy for each degree °C above 28 °C or below 18 °C

    General specifications

    Key features
    WarrantyAnalyzer: 2 years (battery not included)
    Accessories: 1 year (including battery)
    Calibration cycle2 years
    Size (L X W X HD)28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in)
    Weight2.1 kg (4.6 lb)
    Anti-theft protectionSlot to support Kensington lock
    Environmental specifications
    Operating temperature range-10 °C to 50 °C
    Storage temperature range-20 °C to 60 °C
    Operating humidityIEC 60721-3-3: 3K5, modified:
    -10 °C to 30 °C: ≤95 %, no condensation or ice
    35 °C: 70 %
    40 °C: 55 %
    50 °C: 35 %
    IP RatingIEC 60529: IP50
    VibrationIEC 60721-3-3 / 3M2
    Power supply
    Voltage range100 V – 600 V -15 % / +10 % (85 V … 660 V)
    Power consumptionMax. 40 VA
    Mains frequency50/60 Hz (42.5 Hz … 69 Hz)
    UPSLi-Ion battery BP1770 with extended temperature range, customer replaceable
    On-battery runtime: 1.5 hours
    Safety
    GeneralIEC 61010-1: Pollution Degree 2
    Power supplyOvervoltage Category IV 600 V
    With Mains Adapter MA-C8: Overvoltage Category II 300 V
    MeasurementIEC 61010-2-030: CAT IV 600 V, CAT III 1000 V
    Altitudes 2000 m to 4000 mDerate to:
    Power Supply: Category IV 300 V
    With MA-C8 Adapter: Category II 150 V
    Measurement: CAT IV 300 V, CAT III 600 V, CAT II 1000 V
    Quality Fluke 1770 Series Three-Phase Power Quality Analyzers F1770 Fluke 1732 and 1734 F1770 F1732 Electrical Energy Loggers FLUKE 1742 1746 1748 F1742 F1746 for sale