| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | XINCHANGJIANG XINJI |
| Model Number : | JZ-7GY-S002XMT JZ-7GJ-S002XMT JZ-7GY-S400XMT JZ-7GJ-S400XMT JZ-7GY-S220XMT JZ-7GJ-S220 XMT JZ-7GY-S202XMT JZ-7GJ-S202XMT JZ-7GY-S002XMC JZ-7GJ-S002XMC JZ-7GY-S220XMC JZ-7GJ-S220XMC GBZ-284A GBZ-213A GBZ-214A DZB-201 DZB-302 |
| Certification : | CCCI |
| Payment Terms : | Western Union, T/T |
| Supply Ability : | 10-100 |
| Delivery Time : | 7-10days |
XINJI XINCHANGJIANG Jump position monitoring, close position
monitoring, power supply monitoring, dedicated relay
◎ Purpose
This series of XMT intermediate relays is specifically designed for
monitoring switch closing, tripping, power supply, and circuit
breaker. The working current of this product is very small,
Can monitor most switches and circuit breakers. The working voltage
has strong universality, and XMC can monitor all switch circuit
breakers.
Performance
Adopting high-performance sealed imported middle, moisture-proof,
dustproof, uninterrupted, and highly reliable; Accurate operating
voltage, high return coefficient, no jitter, low power consumption,
multiple contacts operating or returning simultaneously (100%
controllability); After the relay is activated, there is a light
indication and a power indication; The electrical and mechanical
lifespan of relays is long
The insulation withstand voltage level is high. Low contact
resistance of the contacts; Good anti-interference characteristics,
suitable for places with strong interference or poor power supply
voltage quality;
The working current is extremely small (≤ 5mA), and the working
voltage range is wide from 50V to 300V (002 type) and 80V to 300V
(220 type or 202 type).
◎ Technical conditions
Rated value of relay: working current 4~6mA, XMC 0.1mA; working
voltage range 80VDC~300VDC (two sets of contacts can be reduced to
50VDC~300VDC) Contact capacity: DC110V, 0.5A
Maintain value: 0.7~1.2 times the rated voltage
Power consumption: Maximum power consumption at 220VDC ≤ 1 1W
Insulation resistance: Use a 1000V megohmmeter to measure the
insulation resistance between each lead terminal and the housing
locking screw, which should not be less than 10MQ.
Insulation withstand voltage: Each lead terminal can withstand
2000V of the power frequency with the locking screw of the shell,
and the contacts in the same group can withstand 1000V of the power
frequency. The test lasts for - minutes without breakdown. Electric
lifespan: DC110V, 0.5A, more than 104 times. .
Mechanical lifespan: The contact has no load for more than 3
million times.
JZ-7GY-S002XMT JZ-7GJ-S002XMT JZ-7GY-S400XMT JZ-7GJ-S400XMT JZ-7GY-S220XMT JZ-7GJ-S220 XMT JZ-7GY-S202XMT JZ-7GJ-S202XMT JZ-7GY-S002XMC JZ-7GJ-S002XMC JZ-7GY-S220XMC JZ-7GJ-S220XMC GBZ-284A GBZ-213A GBZ-214A DZB-201 DZB-302
GLS-3002K GLS-3204K GLS-3320 GLS-3004K DDP-202 JL-8GA/11 JL-8GA/12 JL-8GA/13 JL-8GA/21 JL-8GA/22 JL-8GA/23 JL-8GB/11 JL-8GA/12 JL-8GB/13 JL-8GB/21 JL-8GB/22 JL-8GB/23
|